Our Capabilities

Electric Motor Repair Services

From fractional horsepower fan motors to large industrial frames, we diagnose, rebuild and test electric motors and rotating equipment in our Erie shop.

Electric Motor Rewinding

Full stator and rotor rewinds using premium magnet wire and Class H insulation, wound to original or upgraded specifications.

  • Core loss testing before and after burnout
  • Hand-wound coils for legacy and obsolete frames
  • VPI-grade varnish treatment and bake cycle
  • Surge, hipot and megohm testing before release

AC & DC Motor Repair

Diagnosis and overhaul of single-phase, three-phase, DC and servo motors from fractional horsepower to large industrial frames.

  • Winding failure and insulation breakdown analysis
  • Commutator turning and undercutting
  • Brush rigging and armature service
  • Shaft straightening, sleeving and machining

Pump & Generator Service

Repair and rebuild of centrifugal pumps, submersible pumps, generator heads and portable generator sets.

  • Seal, impeller and wear-ring replacement
  • Generator head rewind and AVR replacement
  • Pressure and flow verification
  • Complete pump-and-motor package rebuilds

Bearing Replacement

Precision bearing removal and installation with induction heating so the fit is right and the life is long.

  • Failure-mode analysis on the old bearing
  • Housing and shaft fit measurement
  • Premium sealed or open bearings to spec
  • Correct lubrication and re-greasing schedule

Dynamic Balancing

Two-plane dynamic balancing of rotors, armatures, fans and impellers to ISO grade tolerances.

  • Vibration analysis before and after
  • Trim balancing on assembled units
  • Documented balance certificates
  • Fan and blower wheel balancing

24/7 Emergency Repair

Line down? We prioritise emergency jobs and work after hours to get critical equipment back into production.

  • After-hours drop-off by arrangement
  • Expedited teardown and quoting
  • Rush parts sourcing
  • Status updates through the repair

On-Site Diagnostics

Field testing at your facility when pulling the motor is the last thing you want to do.

  • Insulation resistance and winding tests
  • Vibration and thermal readings
  • Alignment and mounting inspection
  • Written findings with repair options

Preventive Maintenance

Scheduled inspections and testing programs that catch winding and bearing problems before they shut you down.

  • Motor inventory and criticality ranking
  • Routine insulation and vibration testing
  • Cleaning, re-greasing and re-varnishing
  • Maintenance history for each unit

Equipment We Service

Three-phase induction motors
Single-phase and capacitor-start motors
DC motors and armatures
Servo and gear motors
Submersible and centrifugal pumps
Generator heads and gen-sets
Blowers, fans and blower wheels
Compressor and HVAC motors
Farm, marine and shop equipment motors

Not Sure What Your Motor Needs?

Send us the nameplate data and symptoms — we’ll tell you what it likely needs before you haul it in.